VDC Off Switch
VDC OFF SWITCH
Component Function Check
1. CHECK VDC OFF SWITCH OPERATION
Check that VDC OFF indicator lamp in combination meter turns ON/OFF when VDC OFF switch is operated.
Is the inspection result normal?
YES- Inspection End.
NO- Proceed to diagnosis procedure. Refer to "Diagnosis Procedure" .
Diagnosis Procedure
Regarding Wiring Diagram information, refer to "Wiring Diagram" Electrical Diagrams.
1. CONNECTOR INSPECTION
1.Turn ignition switch OFF.
2.Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
3.Check connectors and terminals for deformation, disconnection, looseness or damage.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace as necessary.
2. CHECK VDC OFF SWITCH
Check VDC OFF switch. Refer to "Component Inspection" .
Is the inspection result normal?
YES- GO TO 3.
NO- Replace VDC OFF switch. Refer to "Removal and Installation" Service and Repair.
3. CHECK VDC OFF SWITCH SIGNAL
With CONSULT.
1.Connect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
2.Turn ignition switch ON.
3.In "DATA MONITOR" select "OFF SW" and check VDC OFF switch signal.
Is the inspection result normal?
YES- Refer to "Work Flow" Work Flow.
NO- GO TO 4.
4. CHECK VDC OFF SWITCH CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect ABS actuator and electric unit (control unit) and VDC OFF switch connectors.
3.Check continuity between ABS actuator and electric unit (control unit) connector E54 terminal 15 and
VDC OFF switch connector M72 terminal 1.
4.Check continuity between ABS actuator and electric unit (control unit) connector terminal E54 terminal 15
and ground.
Is the inspection result normal?
YES- GO TO 5.
NO- Repair or replace malfunctioning components.
5. CHECK VDC OFF SWITCH GROUND CIRCUIT
Check continuity between VDC OFF switch connector M72 terminal 2 and ground.
Is the inspection result normal?
YES- Replace ABS actuator and electric unit (control unit). Refer to "Removal and Installation" Removal And Installation.
NO- Repair or replace malfunctioning components.
Component Inspection
1. CHECK VDC OFF SWITCH
1.Turn ignition switch OFF.
2.Disconnect VDC OFF switch connector.
3.Check continuity between terminals of VDC OFF switch connector.
Is the inspection result normal?
YES- Inspection End.
NO- Replace VDC OFF switch. Refer to "Removal and Installation" Service and Repair.