Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

HVAC System - Automatic

REMOVAL PROCEDURE




1. Remove the air cleaner and duct assembly.
2. Disconnect the battery negative cable.
3. Disconnect the electrical connector from the A/C refrigerant pressure sensor.




4. Remove the refrigerant pressure sensor from the liquid line.

INSTALLATION PROCEDURE

IMPORTANT: Lubricate a new O-ring seal with mineral base 525 Viscosity refrigerant oil.




1. Install the new O-ring seal.

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the refrigerant pressure sensor to the liquid line.

Tighten
Tighten the sensor to 4.7 N.m (41 lb in).




3. Connect the electrical connector to the A/C refrigerant pressure sensor.
4. Connect the battery negative cable.
5. Install the air cleaner and duct assembly.