HO2S Warm-Up Sensor 1/HO2S Warm-Up Sensor 2
Scan Tool Range
00:00 to 99:99 MIN:SEC. Indicates time to warm-up for each
HO2S. The HO2S warm up time is used for the HO2S heater test. The
PCM will run the heater test only after a cold start (determined by engine coolant and intake air temperature at the time of start-up) and only once during an ignition cycle. When the engine is started the PCM will monitor the HO2S voltage. When the HO2S voltage indicates a sufficiently active sensor, the PCM looks at how much time has elapsed since start-up. If the PCM determines that too much time was required for the HO2S to become active, a DTC will set. If the engine was warm when started, HO2S Warm-Up will display the value that was stored the last time the test ran. If info has been cleared, HO2S Warm-Up will display
00:00.