Air Flow Sensor Plate

Fig. 8 Sensor plate rest position:





1. Using 0.004'' feeler gauge check clearance between sensor plate and sensor body at 4 points.
2. If necessary, loosen screw and center sensor plate. Torque screw to 43.2 inch lbs.
3. When plate is in rest position, upper face of sensor plate must be level with beginning of funnel. Plate should be no lower than .020'' below edge of funnel (2), Fig. 8. If necessary position of blade (3) may be altered by bending spring (4). Sensor plate must be installed with TOP or five punch marks facing up.