Service Port HVAC: Service and Repair
SERVICE PORTS REPLACEMENTTOOLS REQUIRED
^ J 39037 Octagon Socket
^ J 39400-A Halogen Leak Detector
REMOVAL PROCEDURE
1. Remove the service port cap.
2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
3. Use the J 39037 to remove the service port.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
1. Install the service port.
Tighten
Tighten the service port to 11 N.m (98 lb in).
2. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
3. Leak test the fittings of the component using J 39400-A.
4. Install the service port cap.
Tighten the cap 1/4 - 1/2 turn after the seal washer contacts to access fitting.