Operation CHARM: Car repair manuals for everyone.

Service Port HVAC: Service and Repair

SERVICE PORTS REPLACEMENT

TOOLS REQUIRED
^ J 39037 Octagon Socket
^ J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE




1. Remove the service port cap.
2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
3. Use the J 39037 to remove the service port.

INSTALLATION PROCEDURE

NOTE: Refer to Fastener Notice in Service Precautions.




1. Install the service port.

Tighten
Tighten the service port to 11 N.m (98 lb in).

2. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
3. Leak test the fittings of the component using J 39400-A.
4. Install the service port cap.
Tighten the cap 1/4 - 1/2 turn after the seal washer contacts to access fitting.