B1398
DTC B1398CIRCUIT DESCRIPTION
The BCM controls the dimming operation of the interior lamps. The BCM applies a 12-volt reference signal to the IP dimming switch. When you move the IP dimming switch, the BCM uses this varying voltage signal in order to apply a pulse width modulation (PWM) voltage in order to control the brightness of the interior illumination lamps
CONDITIONS FOR RUNNING THE DTC
- Voltage supplied to the module is in the normal operating range (approximately 10-16 volts).
- The interior lamps must be ON.
CONDITIONS FOR SETTING THE DTC
- The BCM detects a short to battery positive voltage in the dimming reference voltage circuit.
- The condition is present for longer than 3 ms.
ACTION TAKEN WHEN THE DTC SETS
The BCM stores DTC B1398 in memory.
CONDITIONS FOR CLEARING THE MIL/DTC
- A current DTC B1398 clears when the BCM no longer detects a short to battery positive voltage in the dimming reference voltage circuit.
- A history DTC B1398 clears after 100 consecutive ignition cycles.
DIAGNOSTIC AIDS
- If the DTC B1398 is a history DTC, the fault may be intermittent.
- An intermittent short to battery positive voltage in the following locations may cause an intermittent malfunction to occur:
- The dimming reference voltage circuit
- The IP dimming switch
- The body control module (BCM)
TEST DESCRIPTION
Steps 1-7:
The number(s) below refer to the step number(s) on the diagnostic table.
2. This step tests the dimming reference circuit for a short to battery positive voltage.
3. This step tests the dimming return circuit for a short to battery positive voltage.