B1345
DTC B1345
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Initial Inspection and Diagnostic Overview) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Initial Inspection and Diagnostic Overview) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Initial Inspection and Diagnostic Overview) provides an overview of each diagnostic category.
DTC Descriptor
DTC B1345 04
- Device Ground Circuit Open
Diagnostic Fault Information
Circuit/System Description
The folding top control (FTC) module receives ground at X1, terminal 25. The FTC Module monitors this circuit for proper operation.
Conditions for Running the DTC
The FTC module is active.
Conditions for Setting the DTC
The ground circuit is open or has high resistance.
Action Taken When the DTC Sets
The top is disabled.
Conditions for Clearing the DTC
The fault is no longer present and the top completes one cycle.
Reference Information
Schematic Reference
Folding Top Schematics ([1][2]Convertible Top)
Connector End View Reference
Component Connector End Views (Connector Views)
Description and Operation
Power Folding Top Description and Operation (Power Folding Top Description and Operation)
Electrical Information Reference
* Circuit Testing (Component Tests and General Diagnostics)
* Connector Repairs (Component Tests and General Diagnostics)
* Testing for Intermittent Conditions and Poor Connections (Component Tests and General Diagnostics)
* Wiring Repairs (Component Tests and General Diagnostics)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Circuit/System Testing
1. Ignition OFF, disconnect the X1 harness connector at the FTC module.
2. Test for less than 10 ohms between the ground circuit terminal 25 and ground.
• If greater than the specified range, test the ground circuit for an open/high resistance.
3. If all circuits test normal, replace the FTC module.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
Control Module References (Programming and Relearning) for folding top control module replacement, setup, and programming