WM 870101 Checking air-conditioning system

Tools





Troubleshooting the air conditioning system following complaints about cooling output

Information

The troubleshooting steps shown must be used if complaints are received about the cooling output of the air conditioning system.

-> 8701IN00 Instructions for repairing air conditioning systems and storing spare parts 8701IN00 Instructions for repairing air-conditioning systems and storing spare parts

Information

If it is not possible to clearly detect a leak using a leak detector, then only the leak detector additive supplied by SPEKTRONICS may be used. Leak detector additive: Traserline TP 3860 in dissolved form.

This leak detector additive is available from service equipment providers (e.g. Waeco). => WE1281 Air conditioning service equipment RS 2

For filling this Traser additive, special adapter kits are required, which are also available from service equipment providers (e.g. Waeco).

Information on how to use the air-conditioning system and the procedure for filling it can be found in the operating instructions for the adapter kits.









Troubleshooting the air conditioning system following complaints about noises

Information

The troubleshooting steps shown must be used if complaints are received about noises in the air conditioning system.

-> 8700IN Instructions for repairing air conditioning systems and storing spare parts

Information

If it is not possible to clearly detect a leak using a leak detector, then only the leak detector additive supplied by SPEKTRONICS may be used. Leak detector additive: Traserline TP 3860 in dissolved form.

This leak detector additive is available from service equipment providers (e.g. Waeco). => WE1281 Air conditioning service equipment RS 2

For filling this Traser additive, special adapter kits are required, which are also available from service equipment providers (e.g. Waeco).

Information on how to use the air-conditioning system and the procedure for filling it can be found in the operating instructions for the adapter kits.