P2006

DTC P2006 INTAKE MANIFOLD RUNNER CONTROL STUCK CLOSED(BANK 1)

1. OUTLINE OF DIAGNOSIS
Detect the malfunction of tumble generator valve motor function.
Judge close fixing malfunction when the opening degrees is small even after finishing the tumble generator valve open driving.




2. ENABLE CONDITION

3. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.

4. DIAGNOSTIC METHOD




^ Abnormality Judgment
Judge NG when the continuous time of completing the malfunction criteria below becomes more than 3 seconds.




^ Normality Judgment
Judge OK and clear the NG when the malfunction criteria below are completed.

5. DTC CLEAR CONDITION
^ When the OK idling cycle was completed 40 times in a row
^ When "Clear Memory" was performed

6. MALFUNCTION INDICATOR LIGHT CLEAR CONDITION
^ When the OK driving cycle was completed 3 times in a row
^ When "Clear Memory" was performed

7. FAIL SAFE
Tumble generator valve opening
^ For tumble generator valve all closing points learning, not allowed to update to the closing side.
^ For tumble generator valve all opening points learning, not allowed to update to the opening side.
Tumble generator valve control
^ Output the close signal.

8. ECM OPERATION AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)