Power
Circuit 240
Location: Connects underhood junction block
connector cavity C2 to headlamp switch connector
cavity E
Type: Orange 22 gage wire
Function: This circuit provides power to the headlamp switch.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9K
Location: Connects headlamp switch connector
cavity K to instrument panel junction block connector
cavity B7.
Type: Brown 22 gage wire
Function: This circuit provides power to the instrument panel junction block for the light system.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AJ
Location: Connects instrument panel junction block connector cavity A7 to cluster connector cavity I.
Type: Brown 22 gage wire
Function: This circuit provides power to the I/P cluster for dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit44j
Location: Connects I/P cluster connector cavity H to instrument panel junction block connector cavity B3.
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for the instrument panel dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44P
Location: Connects HVAC connector cavity A to instrument panel junction block connector cavity B3.
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for the instrument panel dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AP
Location: Connects I/P junction block connector cavity C3 to HVAC connector cavity D.
Type: Brown 22 gage wire
Function: This circuit provides power to the HVAC for illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AL
Location: Connects instrument panel junction block connector cavity C3 to I/P dimmer connector cavity C.
Type: Brown 22 gage wire
Function: This circuit provides power to the I/P dimmer.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44
Location: Connects I/P junction block connector cavity Bi to I/P dimmer connector cavity B.
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for all the dimmer illumination components to the I/P dimmer.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AB
Location: Connects instrument panel junction block connector cavity A8 to HVAC dimmer illumination connector cavity A.
Type: Brown 22 gage wire
Function: This circuit provides power to the HVAC dimmer.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AK
Location: Connects instrument panel junction block connector cavity A8 to cigar lighter illumination connector cavity B.
Type: Brown 22 gage wire
Function: This circuit provides power for the cigar lighter illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44K
Location: Connects the cigar lighter illumination connector cavity A to the instrument panel junction block connector cavity B5.
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for the cigar lighter illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44B
Location: Connects the HVAC dimmer illumination connector cavity B to the instrument panel junction block connector cavity B5.
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for the HVAC dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9M
Location: Connects instrument panel junction block connector cavity D3 to radio dimmer illumination connector cavity 6.
Type: Brown 22 gage wire
Function: This circuit provides power to the radio dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44H
Location: Connects radio dimmer illumination
connector cavity 7 to instrument panel junction block
connector cavity B4.
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for the radio dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44L
Location: Connects POD switch dimmer illumination connector cavity L to instrument panel junction block connector cavity B4
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for the POD switch dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AN
Location: Connects instrument panel junction block connector cavity B3 to POD switch dimmer illumination connector cavity M.
Type: Brown 22 gage wire
Function: This circuit provides power to the POD switch dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AC
Location: Connects instrument panel junction block connector cavity B3 to ash tray lamp dimmer illumination connector cavity B.
Type: Brown 22 gage wire
Function: This circuit provides power to the ash tray lamp dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 9AF
Location: Connects instrument panel junction block connector cavity B8 to PRNDL lamp dimmer illumination connector cavity A.
Type: Brown 22 gage wire
Function: This circuit provides power to the PRNDL dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44F
Location: Connects PRNDL dimmer illumination
connector cavity B to instrument panel junction block
connector cavity B2.
Type: Dark Green 22 gage wire
Function: This circuit provides the negative path for the PRNDL dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.
Circuit 44A
Location: Connects ash tray lamp dimmer illumination connector cavity A to instrument panel junction block connector cavity Bi.
Type: Dark Green 22 gage wire
Function: This circuit provides negative path for the ash tray lamp dimmer illumination.
Check for OPENS/SHORTS.
Repair as needed.
If this component is good, go to the next item indicated on the "Complaint-Condition" chart.