Refrigerant
HEATING / AIR CONDITIONING: REFRIGERANT: ON-VEHICLE INSPECTION; 2013 MY FR-S [03/2012 -]
1. INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET
(a) This method uses a manifold gauge set to locate problem areas. Read the manifold gauge pressure when the test conditions are established.
Test conditions:
* Temperature at the air inlet with the air recirculation switch set at RECIRC is 30 to 35°C (86 to 95°F).
* Engine is running at 1500 rpm.
* All doors are fully open.
* Blower speed control switch is set to HI.
* A/C switch is on.
Gauge readings (Reference):
(1) Normally functioning refrigeration system.
Gauge Reading:
(2) The A/C system periodically changes between normal and improper function due to moisture in the refrigerant system.
(3) The A/C system does not function effectively due to insufficient refrigerant.
(4) The A/C system does not function effectively due to poor circulation of the refrigerant.
(5) The A/C system does not function or functions intermittently because the refrigerant does not circulate.
(6) The A/C system does not function effectively due to the system being overcharged with refrigerant or insufficient cooling of the condenser.
(7) The A/C system does not function due to air in the refrigeration system.
CAUTION:
The low-pressure piping may be very hot and cause serious burns.
NOTICE:
These gauge indications occur when the refrigeration system opens and the system is charged with refrigerant without vacuum purging.
(8) The A/C system does not function effectively due to an expansion valve malfunction.
(9) The A/C system does not function due to a defective compressor.