Entire Combination Meter Does Not Operate
METER / GAUGE / DISPLAY: METER / GAUGE SYSTEM: Entire Combination Meter does not Operate; 2013 MY FR-S [03/2012 -]
- Entire Combination Meter does not Operate
DESCRIPTION
This circuit is the power source circuit for the combination meter assembly.
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
(a) Disconnect the D7 combination meter assembly connector.
(b) Measure the voltage according to the value(s) in the table below.
Standard Voltage:
(c) Measure the resistance according to the value in the table below.
Standard Resistance:
(d) Reconnect the D7 combination meter assembly connector.
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE COMBINATION METER ASSEMBLY Removal