Hose/Line HVAC: Service and Repair
Flexible HoseRemoval and Installation
CAUTION:
With the following cautions, replace flexible hoses with new ones if they are damaged or swollen.
- The flexible hoses should be free from twists and tension after they have been connected.
- The flexible hoses must not be bent or twisted forcibly.
1. Disconnect battery negative terminal.
2. Discharge refrigerant using refrigerant recovery system.
3. Remove low-pressure hose (A):
CAUTION: Plug the opening to prevent foreign matter from getting in.
1. Remove hose attaching bolts (C).
2. Remove the hose assembly from evaporator unit.
3. Disconnect the low-pressure hose (A) from the hose assembly (E).
4. Remove high-pressure hose (B):
CAUTION: Plug the opening to prevent foreign matter from getting in.
1. Remove hose attaching bolt (D).
2. Remove high-pressure hose (B).
5. Install in the reverse order of removal.
6. Charge refrigerant.