Operation CHARM: Car repair manuals for everyone.

With VDC

VDC Sequence Control

OPERATION
1) While VDC sequence control is being performed, the operation of the hydraulic unit can be checked using the brake tester or pressure gauge after the hydraulic unit solenoid valve operation.
2) VDC sequence control can be started by the Subaru Select Monitor.

VDC SEQUENCE CONTROL WITH SUBARU SELECT MONITOR

NOTE:
In the event of any trouble, sequence control will not operate.

1) Connect the Subaru Select Monitor to data link connector under the driver's side instrument panel lower cover.
2) Turn the ignition switch to ON.
3) Run the "PC application for Subaru Select Monitor".
4) Set the Subaru Select Monitor to "Brake Control System" mode.
5) When the "VDC Inspection Mode" is selected from the "Function check sequence" menu, the "VDC sequence control" will start.
6) Press the [OK] after "Press OK" is displayed.
7) Operation points will be displayed on Subaru Select Monitor.

CONDITIONS FOR VDC SEQUENCE CONTROL








NOTE:
The control operation starts at point A.

SPECIFICATION

CONDITIONS FOR COMPLETION OF VDC SEQUENCE CONTROL
When the following conditions develop, the VDC sequence control stops and VDC operation is returned to the normal control mode.
^ When the speed of at least one wheel reaches 10 km/h (6 MPH).
^ When the brake pedal is pressed during sequence control and the stop light switch is set to ON.
^ After completion of VDC sequence control.
^ When a malfunction is detected.