Hot Idle Compensator (Non Comp. Controlled): Testing and Inspection
Fig. 8 Checking Hot Idle Compensator Operation:
1.
Remove air cleaner.
2.
Disconnect vacuum hose from HIC.
3.
Check temperature at HIC with thermometer.
4.
Blow air into HIC. HIC should be closed at temperatures below 113°F and open at temperatures above 149°F,
Fig. 8. 5.
Reconnect vacuum hose, and reinstall air cleaner.