Blower Motor Switch: Testing and Inspection
Blower Switch Testing:
1.
Check power source line between terminal C of wiring connector and body ground.
2.
Check ground connection between connector terminals E, M1, M2, H, and body ground.
3.
Check switch continuity as shown on image chart.
4.
If not as specified, replace switch.