Exhaust Gas Recirculation: Specifications
EVAP Temperature Switch
Below 48°C (118°F)
ON (Continuity)
Above 60°C (140°F)
OFF (No Continuity)
EGR BVSV
Below 40°C (104°F)
Open (
EGR Disabled)
Above 54°C (129°F)
Closed (
EGR Enabled)
HAI Control Valve (HIC)
Below 26°C (79°F)
Intake Air Hot
Above 34°C (93°F)
Intake Air Cool
Engine Vacuum At Idle
450 mmHg (17.72 in.Hg, 60 kPa) or more