Operation CHARM: Car repair manuals for everyone.

Manifold Gauge Installation/Removal

SET ON




1. CONNECT CHARGE HOSE TO MANIFOLD GAUGE SET

Tighten the nuts by hand.

CAUTION: Do not connect the wrong hoses.

2. CONNECT QUICK DISCONNECT ADAPTER TO CHARGING HOSES
Tighten the nuts by hand.

3. CLOSE BOTH HAND VALVE OF MANIFOLD GAUGE SET
4. REMOVE CAPS FROM SERVICE VALVE ON REFRIGERANT LINE




5. CONNECT QUICK DISCONNECT ADAPTER TO SERVICE VALVES


HINT: Push the quick disconnect adapter onto the service valve, then slide, then slide the sleeve of the quick disconnect adapter downward to lock it.

SET OFF




1. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE SET
2. DISCONNECT QUICK DISCONNECT ADAPTERS FROM SERVICE VALVES ON REFRIGERANT LINE


HINT: Slide the sleeve of the quick disconnect adapter upward to unlock the adapter and remove it from the service valve.

3. INSTALL CAPS TO SERVICE VALVES ON REFRIGERANT LINE