Air/Fuel Ratio Sensor
INSPECTIONINSPECT HEATER RESISTANCE OF A/F SENSORS (Bank 1 sensor 1, Bank 2 Sensor 1)
a. Disconnect the A/F sensor connector.
b. Using an ohmmeter measure the resistance between terminals +B and HT.
- Resistance:
- At 20 °C (68 °F) 0.8 - 1.4 Ohms
- At 800 °C (1,472 °F) 1.8 - 3.2 Ohms
- If the resistance is not as specified, replace the sensor.
- Torque: 44 Nm (440 kg.cm, 31 ft.lb)
c. Reconnect the A/F sensor connector.