Power Quarter Window System
Power Rear Quarter Window SystemINSPECTION
1. INSPECT POWER QUARTER WINDOW SWITCH CONTINUITY
If continuity is not as specified, replace the switch.
2. Left side:
INSPECT POWER VENT WINDOW MOTOR OPERATION
a. Connect the positive (+) lead from the battery to terminal 1 and the negative (-) lead to terminal 2, and check that the window link moves to OPEN position.
b. Reverse the polarity and check that the window link moves to CLOSE position.
If operation is not as specified, replace the window motor.
3. Right side:
INSPECT POWER VENT WINDOW MOTOR OPERATION
a. Connect the positive (+) lead from the battery to terminal 2 and the negative (-) lead to terminal 1, and check that the window link moves to OPEN position.
b. Reverse the polarity and check that the window link moves to CLOSE position.