Component Tests and General Diagnostics
INSPECTION1. INSPECT CARGO LIGHT SWITCH CONTINUITY
a. Remove the center cluster finish panel.
b. Disconnect the connector from the center cluster integration.
c. Check the continuity exists between terminal 12 and terminal 1, with the switch ON.
d. Check that no continuity exists between terminal 12 and terminal 1, with the switch OFF.
If continuity is not as specified, replace the switch.
2. INSPECT CARGO LIGHT ASSEMBLY CONTINUITY
Using the ohmmeter, check that continuity exists between terminal 3 and terminal 2.
If continuity is not as specified, replace the light assembly or bulb.