HV Relay Assembly
INSPECTION1. SMR1 AND SYSTEM MAIN RESISTOR
a. Measure the resistance between the 3 (CON1) and 4 (GND) terminals of the connector for the relay drive of the HV relay assembly.
Standard resistance:
70 to 165 (at -30 degrees C (-22 degrees F) to 80 degrees C (176 degrees F))
b. Increase battery voltage between the 3 (CON1) and 4 (GND) terminals of the connector for the relay drive of the HV relay assembly, and measure the resistance between the terminal of the HV battery side positive connector and the w/ convertor inverter assembly side positive terminal of the HV relay assembly.
HINT: The standard resistance indicates the resistance of the system main resistor.
Standard resistance:
28.5 to 31.5 Ohms
2. SMR2
a. Measure the resistance between the 1 (CON2) and 4 (GND) terminals of the connector for the relay drive of the HV relay assembly.
Standard resistance:
20 to 60 (at -35 degrees C (-31 degrees F) to 80 degrees C (176 degrees F))
b. Increase battery voltage between the 1 (CON2) and 4 (GND) terminals of the connector for the relay drive of the HV relay assembly, and measure the resistance between the terminal of the HV battery side positive connector and the w/ converter inverter assembly side positive terminal of the HV relay assembly.
Standard resistance:
Below 1 Ohm
3. SMR3
a. Measure the resistance between the 2 (CON3) and 4 (GND) terminals of the connector for the relay drive of the HV relay assembly.
Standard resistance:
20 to 60 (at -35 degrees C (-31 degrees F) to 80 degrees C (176 degrees F))
b. Increase battery voltage between the 2 (CON3) and 4 (GND) terminals of the connector for the relay drive of the HV relay assembly, and measure the resistance between the terminal of the HV battery side negative connector and the w/ converter inverter assembly side negative terminal of the HV relay assembly.
Standard resistance:
Below 1 Ohm