Removal
1GR-FE COOLING: WATER PUMP: REMOVAL
REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
2. REMOVE FAN
Refer to the procedures up to "REMOVE FAN" Removal.
3. REMOVE V-BANK COVER Removal
4. REMOVE AIR CLEANER ASSEMBLY Removal
5. REMOVE GENERATOR ASSEMBLY
Refer to the procedures up to "REMOVE GENERATOR ASSEMBLY" Removal
6. REMOVE WATER INLET
(a) Disconnect the 2 radiator hoses.
(b) Disconnect the 5 water by-pass hoses.
(c) Remove the 5 bolts and water inlet.
(d) Remove the O-ring from the water outlet pipe.
(e) Remove the gasket from the water pump.
7. REMOVE NO. 2 IDLER PULLEY SUB-ASSEMBLY Removal
8. SEPARATE COOLER COMPRESSOR ASSEMBLY Removal
9. REMOVE V-RIBBED BELT TENSIONER ASSEMBLY Removal
10. SEPARATE VANE PUMP ASSEMBLY Removal
11. REMOVE WATER PUMP ASSEMBLY
(a) Remove the 17 bolts, then remove the water pump and gasket.