Inspection
DIFFERENTIAL: DIFFERENTIAL LOCK SYSTEM: INSPECTION
INSPECTION
1. INSPECT CENTER DIFFERENTIAL LOCK SWITCH
(a) Check the resistance.
(1) Measure the resistance using an ohmmeter.
Standard:
If the result is not as specified, replace the center differential lock switch.
2. INSPECT NO. 1 TRANSFER INDICATOR SWITCH
(a) Check the resistance.
(1) Measure the resistance using an ohmmeter.
Standard:
If the result is not as specified, replace the No. 1 transfer indicator switch.