Part 2
HYBRID / BATTERY CONTROL: HYBRID CONTROL SYSTEM: P0AA6-526,P0AA6-611,P0AA6-612,P0AA6-613,P0AA6-614: Hybrid Battery Voltage System Isolation Fault
P0AA6-614 - Hybrid Battery Voltage System Isolation Fault
Continued
(e) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Result:
B -- CHECK MOTOR CABLE
A -- REPLACE INVERTER WITH CONVERTER ASSEMBLY Components
10. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE)
CAUTION:
Be sure to wear insulated gloves.
(a) Turn the power switch off.
(b) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(c) Remove the inverter terminal cover from the inverter with converter assembly.
HINT
Make sure that no foreign objects have entered or contaminated the inverter with converter assembly.
(d) Disconnect the motor cable e1 and generator cable f1 from the inverter with converter assembly.
(e) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- CHECK MOTOR CABLE
OK -- Continue to next step.
11. CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR CABLE)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- CHECK GENERATOR CABLE
OK -- Continue to next step.
12. CHECK HIGH VOLTAGE DIRECT CURRENT AREA
CAUTION:
Be sure to wear insulated gloves.
(a) Turn the power switch off.
(b) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(c) Disconnect the frame wire T1 from the inverter with converter assembly.
HINT
Make sure that no foreign objects have entered or contaminated the connector of the frame wire T1.
(d) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- CHECK FRAME WIRE
OK -- Continue to next step.
13. CHECK NO. 2 ENGINE WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the No. 2 engine wire (air conditioning harness) E2 from the inverter with converter assembly.
(c) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- CHECK NO. 2 ENGINE WIRE
OK -- REPLACE INVERTER WITH CONVERTER ASSEMBLY Components
14. CHECK NO. 2 ENGINE WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the No. 2 engine wire (air conditioning harness) E1 from the compressor with motor assembly.
Text in Illustration
(c) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- REPLACE NO. 2 ENGINE WIRE
OK -- AIR CONDITIONING SYSTEM (P0AA6-611) P0AA6
15. CHECK FRAME WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the frame wire T4 and T3 from the hybrid battery junction block.
HINT
For the removal and installation procedures related to the frame wire, Components.
(c) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
NG -- REPLACE FRAME WIRE Components
OK -- REPLACE HYBRID BATTERY JUNCTION BLOCK Components
16. CHECK HYBRID BATTERY JUNCTION BLOCK
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the high voltage cable connector of the HV battery h2 and k2 from the hybrid battery junction block.
(c) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
NG -- REPLACE HYBRID BATTERY JUNCTION BLOCK Components
OK -- REPLACE HV BATTERY Components
17. CHECK MOTOR CABLE
CAUTION:
Be sure to wear insulated gloves.
(a) Turn the power switch off.
(b) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(c) Disconnect the motor cable from the hybrid vehicle transaxle assembly Components.
(d) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- REPLACE MOTOR CABLE Components
OK -- REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY Components
18. CHECK GENERATOR CABLE
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the generator cable from the hybrid vehicle transaxle assembly Components.
(c) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- REPLACE GENERATOR CABLE Components
OK -- REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY Components
19. CHECK MOTOR CABLE
CAUTION:
Be sure to wear insulated gloves.
(a) Turn the power switch off.
(b) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(c) Disconnect the motor cable from the hybrid vehicle transaxle assembly Components.
(d) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- REPLACE MOTOR CABLE Components
OK -- Continue to next step.
20. CHECK GENERATOR CABLE
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the generator cable from the hybrid vehicle transaxle assembly Components.
(c) Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
NOTICE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance:
Text in Illustration
NG -- REPLACE GENERATOR CABLE Components
OK -- REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY Components