Installation
HEATING / AIR CONDITIONING: FRONT BLOWER MOTOR: INSTALLATION
1. PRECAUTION (w/ Solar Ventilation System)
NOTICE:
Make sure to turn off the solar ventilation switch to prevent the blower motor from operating unexpectedly.
2. INSTALL FRONT BLOWER MOTOR SUB-ASSEMBLY (w/o Solar Ventilation System)
(a) Install the front blower motor sub-assembly with the 3 screws.
NOTICE:
Do not install the front blower motor sub-assembly if it has been damaged or impacted.
(b) Engage the clamp and connect the connector.
(c) Install the quick heater connector screw.
3. INSTALL FRONT BLOWER MOTOR SUB-ASSEMBLY (w/ Solar Ventilation System)
(a) Install the front blower motor sub-assembly with the 3 screws.
NOTICE:
Do not install the front blower motor sub-assembly if it has been damaged or impacted.
(b) Engage the clamp and connect the connector.
(c) Install the quick heater connector screw.
4. INSTALL NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY Installation