Entire Combination Meter Does Not Operate
METER: METER / GAUGE SYSTEM: Entire Combination Meter does not Operate
- Entire Combination Meter does not Operate
DESCRIPTION
This circuit provides power to the combination meter assembly.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. INSPECT FUSE (GAUGE2, ECU-B, IG2)
(a) Remove the GAUGE2 fuse from the instrument panel junction block.
(b) Remove the ECU-B fuse from the engine room No. 2 relay block.
(c) Remove the IG2 fuse from the engine room No. 1 relay block.
(d) Measure the resistance of the fuses.
Standard resistance:
Below 1 Ohms
NG -- REPLACE FUSE
OK -- Continue to next step.
2. INSPECT IG2 RELAY
(a) Remove the IG2 relay from the No. 1 relay block.
(b) Measure the resistance of the relay.
Standard resistance:
NG -- REPLACE IG2 RELAY
OK -- Continue to next step.
3. CHECK WIRE HARNESS (COMBINATION METER - BATTERY AND BODY GROUND)
(a) Disconnect the E19 meter connector.
(b) Measure the voltage of the wire harness side connector.
Standard voltage:
(c) Measure the resistance of the wire harness side connector.
Standard resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE COMBINATION METER ASSEMBLY