Removal
P410 HYBRID TRANSMISSION / TRANSAXLE: MOTOR CABLE: REMOVAL
1. PRECAUTION
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Service Precautions.
2. REMOVE SERVICE PLUG GRIP
Removal
3. REMOVE NO. 1 ENGINE UNDER COVER
4. DRAIN COOLANT (for Inverter) Coolant (for Inverter)
5. REMOVE RADIATOR SUPPORT OPENING COVER Removal
6. REMOVE NO. 1 INVERTER BRACKET Removal
7. DISCONNECT ENGINE ROOM MAIN WIRE Removal
8. REMOVE INVERTER COVER Removal
9. CHECK TERMINAL VOLTAGE Removal
10. DISCONNECT FRAME WIRE Removal
11. DISCONNECT GENERATOR CABLE Removal
12. DISCONNECT MOTOR CABLE Removal
13. DISCONNECT NO. 2 ENGINE WIRE Removal
14. INSTALL INVERTER COVER Removal
15. DISCONNECT NO. 2 ENGINE ROOM WIRE Removal
16. DISCONNECT WATER HOSE Removal
17. REMOVE INVERTER WITH CONVERTER ASSEMBLY Removal
18. REMOVE INVERTER RESERVE TANK ASSEMBLY Removal
19. REMOVE INVERTER TRAY BRACKET Removal
20. REMOVE MOTOR CABLE
NOTICE:
Wear insulated gloves.
(a) Disconnect the 3 clamps.
(b) Remove the 2 bolts and slide the motor cable connector shell back.
(c) Disengage the 2 claws to remove the terminal cap.
(d) Remove the 3 bolts and motor cable from the hybrid transaxle assembly.