Thermo-Time Switch, Checking
Thermo-time switch, checking
engine cold, air temperature below 2O° C (68° F)
- Pull electrical connector off cold-start valve
- Connect test light
- Pull wire off ignition coil terminal 1
- Operate starter
Test light must light up brightly after 11 seconds (maximum) test light must dim or go off