System Specifications
COLD START VALVE Resistance between connector terminals
6 to 13 ohms
DIFFERENTIAL PRESSURE REGULATOR resistance between connector terminals
17.5 to 21 ohms
Current reading at idle
Checking value
4 to 16 mA
Adjusting value
10 ± 1 mA
FUEL PUMP maximum current draw
8.5 amps