System Specifications
COLD START VALVE Resistance between connector terminals
6 to 13 ohms
DIFFERENTIAL PRESSURE REGULATOR Resistance between connector terminals
15 to 20 ohms
Control current readings
At idle checking value
0 to 5 mA
At idle adjusting value
2.5 ± 2.5 mA
After start enrichment (6 to 9 seconds)
15 to 25 mA
Warm-up enrichment
9 to 15 mA
FUEL PUMP maximum current draw
8.5 amps