Ambient Temperature Sensor / Switch HVAC: Testing and Inspection
Ambient Temperature Switch F38, Checking Ambient temperature switch closes above 7°C (45°F) and opens below -1°C (30°F)
-
set multimeter
US 1119 to ohm scale
-
connect test leads to terminals on ambient temperature switch
-
must be continuity (
0 ohm) if temperature is above
7°C (45°F)