Operation CHARM
: Car repair manuals for everyone.
Home
>>
Volvo
>>
1988
>>
240 L4-2.3L SOHC VIN 88 B230F
>>
Repair and Diagnosis
>>
Powertrain Management
>>
Computers and Control Systems
>>
Testing and Inspection
>>
Component Tests and General Diagnostics
>>
Oxygen Sensor Feedback System
>>
Malfunction Tests
>>
Malfunction Test 9
Malfunction Test 9
1.
If CO reading increases when connecting electrical connector at
oxygen sensor
, replace oxygen sensor.
2.
Perform ``System Test.''