Signal Faulty - Intermittent Fault
Checking The Wiring
- Ignition off.
- Disconnect connector from passenger airbag.
- Ignition on.
Connect an oscilloscope between the passenger airbag #1 and ground. Check for an intermittent short circuit to ground, as described in Checking wiring and terminals - Intermittent faults.
Checking Wiring and Terminals - Intermittent Faults
The oscilloscope should now show a spiked pulse with a period time of approximately 500 ms.