Intermittent Fault
Intermittent fault
- Ignition off.
- Disconnect the control module connector.
Check the cable between control module connector #21 and collision sensor connector #1.
Take a reading for an intermittent short-circuit to ground according to Checking wiring and terminals - Intermittent faults.
Also check the ground lead between control module connector #46 and collision sensor connector #2.
Measure for an open-circuit according to Checking wiring and terminals - Intermittent faults.
Remedy as necessary.
Checking Wiring and Terminals - Intermittent Faults