Signal Too High. Intermittent Fault
Intermittent Fault
Check the wiring between transmission control module (TCM) terminal #A52 (#A52) and transmission connector terminal #D3. Check the wiring between control module terminal #B1O (#A70) and transmission connector terminal #D4.
Check for an intermittent short-circuit to supply voltage according to Checking wiring and terminals. Intermittent faults.
HINT: Check solenoid SLT. Measure the resistance between terminals #D3 and #D4 on transmission connector D. The resistance should be 5 - 5.6 Ohms at 20 degree C.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box.
- To disconnect the transmission connectors, see Connectors, transmission, disconnecting/connecting.
- For information about signals, see Signal description. Transmission control module (TCM).
Select "Continue" when the fault has been repaired.
Continue with Next Procedure. Fault-Tracing Information - Intermittent Fault