Operation CHARM: Car repair manuals for everyone.
Manuals through 2025 now available!

Our trusted friends have launched a new website named LEMON, which has newer manuals. It also contains all the CHARM manuals.

LEMON is the spiritual successor to CHARM, I recommend you try it!

Link: lemon-manuals.la or lemon-manuals.org.ua

(Some people have issue connecting. LEMON is investigating. For now, use Firefox or change your DNS server)

Or, hide this message: temporarily or permanently

Checking Power Supply To RTI Control Module






Checking power supply to RTI control module

Check function




- Ignition off.
Try to activate the RTI system with the remote control.





Can the RTI system be activated?

Yes - Checking cables

No - No Fault Found

-------------------------------------------------

Checking cables
Check the cable between overload relay 2/30 terminal 3 and the RTI control module #B2 for a short-circuit to supply voltage according to Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.

Note! Check the other cables in the relay circuit for a short-circuit to supply voltage Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.

Check control cable between overload relay 2/30 terminal 3 and ignition switch for a short-circuit to supply voltage for a short-circuit to supply voltage Checking wiring and terminals. Permanent fault Checking Wiring and Terminals. Permanent Fault.
If no faults are detected in the cables, try a new relay.
Remedy as necessary.

Other information:









-------------------------------------------------