Signal Too Low
Signal too low
Checking for permanent or intermittent faults
- Ignition on
- Operate the sun roof to full tilt.
Check that the automatic operation of the sun roof works.
Was the function OK?
Yes - Verification
No - Checking the wiring
-------------------------------------------------
Checking the wiring
Check the connector to the sun roof motor. Check for contact resistance and oxidation. Check for loose connections.
Other information
- To access the sun roof motor connector, see Electric motor, sun roof, replacing Service and Repair
- Checking wiring and terminals Checking Wiring And Terminals.
Continue - Replacing the component
-------------------------------------------------
Replacing the component
- Replace the sun roof motor. See Electric motor, sun roof, replacing Service and Repair
- Ignition off
- Reinstall the components, reconnect the connectors etc.
- Ignition on.
Check that automatic closing of the sun roof works by pressing forward the switch 2 steps.
Does the automatic closing of the sun roof work?
Yes - Verification
No - Replacing the component
-------------------------------------------------
Replacing the component
Replace the sun roof control module according to Sun roof module (SRM), replacing Service and Repair.
Continue - Verification
-------------------------------------------------
Verification
Verification
Verification
Hint: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect the connectors, install the components, etc.
- Ignition on.
Check that the automatic sunroof closing works.
Does it work?
Yes - VERIFIED
No - VERIFICATION FAILED
------------------------
VERIFIED - Fault Found
VERIFICATION FAILED - Fault-tracing information
-------------------------------------------------
Fault-tracing information
Information
Fault-tracing information
The fault should have been detected and remedied. As this is not the case fault-tracing has failed.
Exit fault-tracing for this diagnostic trouble code (DTC) or make another attempt.
Do you want to exit fault-tracing?
Yes - FAULT-TRACING FAILED
No - Attempt New Test
------------------------
Attempt New Test - Checking the wiring
FAULT-TRACING FAILED - No Fault Found
-------------------------------------------------