Secondary Air Injection Combination Valve, Version 1, Checking For Function and Leaks






Secondary Air Injection Combination Valve, Version 1, Checking for Function and Leaks

Procedure

Hose connections properly sealed.

- Disconnect air guide hose - 1 - from Secondary Air Injection (AIR) combi-valve.





The illustration shows the left secondary air injection combination valve.

Ignore items - 2 and 3 -.

- Connect an appropriate assisting hose - arrow - to Secondary Air Injection (AIR) combi-valve.





- Blow into the assisting hose using light pressure (do not use pressurized air).

Secondary Air Injection (AIR) combination valve must be closed, it must not be possible to blow through.

- Blow into the assisting hose using higher pressure (do not use pressurized air).

The Secondary Air Injection (AIR) combination valve must open, it must be possible to blow through.

If the switching point is not recognized:

- Replace Secondary Air Injection (AIR) combi-valve.