Blower Motor Malfunction
Blower Motor Malfunction
Test Description
Step 1 - Step 9:
Step 10 - Step 13:
The numbers below refer to the step numbers on the diagnostic table.
2. This step will determine if one or more blower speeds are inoperative.
3. This step determines if the HVAC control module and blower motor control processor are attempting to control the blower motor speed.
5. The measured voltage on the blower motor speed control circuit should steadily decrease from 4.6-1.1 volts as the blower motor speed is adjusted from the minimum speed position to the maximum speed position.