L5 Check For Short to Ground Along Harness Circuit 599
- Set ohmmeter on 20K ohm scale.- Measure resistance between antilock electronic control module harness connector Pin 13 (PK/LG) and chassis ground.
- Is resistance less than 20K ohms?
YES -- Repair short in Circuit 599 (PK/LG) between antilock electronic control module and RABS valve. Go to L6. L6 Clear DTC/Pull DTC
NO -- Conflict of information. Repeat L3. L3 Check Integrity of RABS Valve Connection