Operation CHARM: Car repair manuals for everyone.

L5 Check For Short to Ground Along Harness Circuit 599

- Set ohmmeter on 20K ohm scale.

- Measure resistance between antilock electronic control module harness connector Pin 13 (PK/LG) and chassis ground.

- Is resistance less than 20K ohms?

YES -- Repair short in Circuit 599 (PK/LG) between antilock electronic control module and RABS valve. Go to L6. L6 Clear DTC/Pull DTC

NO -- Conflict of information. Repeat L3. L3 Check Integrity of RABS Valve Connection