C1210 Front Right Dump Valve
POSSIBLE SOURCE(S):- Open/shorted valve solenoid.
- Open/shorted valve Circuit 498 (PK) between the antilock brake control module and HCU.
- Shorted/open antilock brake control module valve driver.
- Defective valve feedback circuit within antilock brake control module.
- Circuit 498 shorted to ground.
ACTION(S) TO TAKE:
- Go to Pinpoint Test F.