Test J: One Turn Signal/Hazard Lamp Is Inoperative
PINPOINT TEST J: ONE TURN SIGNAL/HAZARD LAMP IS INOPERATIVEJ1-J3:
Normal Operation - Except STX
When the multifunction switch is placed in the LH or RH TURN position, the multifunction switch routes the voltage to the LH and RH front turn lamps through circuits 3 (LG/WH) and 2 (WH/LB), respectively. The multifunction switch also routes the voltage to the LH and RH rear lamps through the existing stoplamp circuitry. Ground for the turn lamps is provided through circuit 57 (BK).
Normal Operation - STX
When the multifunction switch is placed in the LH or RH TURN position, the multifunction switch routes the voltage to the LH and RH front turn lamps through circuits 3 (LG/WH) and 2 (WH/LB), respectively. The multifunction switch also routes the voltage to the LH and RH rear turn lamps through circuits 9 (LG/OG) and 5 (OG/LB), respectively. Ground for the turn lamps is provided through circuit 57 (BK).
Possible Causes
- Circuit 2 (WH/LB) open
- Circuit 3 (LG/WH) open
- Circuit 5 (OG/LB) open
- Circuit 9 (LG/OG) open
- Circuit 57 (BK) open
- Multifunction switch