Test E: The Roof Opening Panel Does Not Open or Close

PINPOINT TEST E: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSE

NOTE: The roof opening panel motor initialization procedure must be done when repairs are carried out on part of the roof opening panel system, including: any time the roof opening panel motor has been removed from the roof opening panel assembly, a new roof opening panel motor has been installed or when a new roof opening panel assembly has been installed.

Normal Operation
The roof opening panel uses an integrated motor and module to operate the roof opening panel. A new roof opening panel motor/module is installed as an assembly.

The roof opening panel motor/module is energized by voltage on circuit 400 (LB/BK) when the key is in the ACC or RUN position. The roof opening panel motor/module grounds circuit 1173 (BN/OG) to the roof opening panel switch. When the roof opening panel switch is pressed, the roof opening panel motor/module receives a ground signal to circuit 1174 (WH/RD) for CLOSE or circuit 1175 (TN/RD) for OPEN.

This pinpoint test is intended to diagnose the following:
- Fuse(s)
- Wiring, terminals or connectors
- Inoperative roof opening panel switch
- Inoperative roof opening panel motor/module assembly
- Inoperative accessory delay relay
- Roof opening panel motor not initialized


E1-E5:






E5-E6:






E7-E9:






E10: