Pinpoint Tests AR: DTC B1363
Instrumentation, Message Center and Warning Chimes
Pinpoint Tests
Pinpoint Test AR: DTC B1363
Refer to Wiring Diagram Set 13, Power Distribution/SJB for schematic and connector information. Diagrams By Number
Normal Operation
- DTC B1363 (Ignition Start Circuit Failure) - a continuous memory DTC that sets in the Instrument Cluster (IC) if the IC receives an ignition START message for more than 15 seconds from the Smart Junction Box (SJB) over the Medium Speed Controller Area Network (MS-CAN) communication bus.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- Ignition switch
- SJB
PINPOINT TEST AR: DTC B1363
-------------------------------------------------
AR1 CARRY OUT THE IC SELF-TEST
- Enter the following diagnostic mode on the scan tool: IC Self-Test.
- Clear the DTCs. Repeat the IC self-test.
- Is DTC B1363 still present?
Yes
GO to AR2.
No
The system is operating normally at this time. The concern may have resulted from an intermittent network concern.
-------------------------------------------------
AR2 RETRIEVE THE RECORDED DTCs FROM THE SJB SELF-TEST
- Check for recorded SJB DTCs from the self-test.
- Are any SJB DTCs recorded?
Yes
REFER to Body Control Systems.
No
GO to AR3.
-------------------------------------------------
AR3 CHECK THE SJB IGNITION SWITCH PID
- Disconnect: Starter Relay.
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: SJB DataLogger.
- Monitor the SJB ignition switch (IGN_S_ECU) PID with the ignition switch in the START position then in the RUN position.
- Does the PID indicate YES with the ignition in the START position and NO in the RUN position?
Yes
GO to AR6.
No
GO to AR4.
-------------------------------------------------
AR4 CHECK CIRCUIT CDC35 (BU/WH) FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: SJB C2280b.
- Disconnect: Ignition Switch C250.
- Ignition ON.
- Measure the voltage between the ignition switch C250-7, circuit CDC35 (BU/WH), harness side and ground.
- Is any voltage present?
Yes
REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.
No
GO to AR5.
-------------------------------------------------
AR5 CHECK THE IGNITION SWITCH OPERATION
- Ignition OFF.
- Connect: Ignition Switch C250.
- Place the key in the START position.
- Measure the voltage between the SJB C2280b-32, circuit CDC35 (BU/WH), harness side and ground.
- Ignition ON.
- Measure the voltage between the SJB C2280b-32, circuit CDC35 (BU/WH), harness side and ground.
- Is the voltage greater than 10 volts with the ignition switch in the START position then drop to 0 volts with the ignition switch in the RUN position?
Yes
GO to AR6.
No
INSTALL a new ignition switch. CLEAR the DTCs. REPEAT the self-test.
-------------------------------------------------
AR6 CHECK FOR CORRECT SJB MODULE OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify that the concern is still present.
- Is the concern still present?
Yes
INSTALL a new SJB. TEST the system for normal operation.
No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
-------------------------------------------------