Roof Opening Panel Rear Trough Guide
Roof Opening Panel Rear Trough Guide
Removal and Installation
NOTE: The roof opening panel must be initialized when repairs are carried out on any part of the roof opening panel, including: whenever the roof opening panel has been removed from the roof opening panel assembly, a new roof opening panel motor/module has been installed or when a new roof opening panel assembly has been installed. For additional information, refer to Roof Opening Panel Motor Initialization Programming and Relearning.
1. Remove the roof opening panel glass. For additional information, refer to Roof Opening Panel Glass Roof Opening Panel Glass.
2. Remove the 2 trough guide retaining screws and the trough from the trough guide assembly.
- To install, tighten to 1 Nm (9 lb-in).
3. Disconnect the trough guide rods from the lifter arm assemblies.
4. Position the glass frame to the VENT position.
5. Slide the trough guide back to the slot (approximately 15 mm [0.6 in]) cut in track.
- Pull the front of the guide up.
- Holding the guide rod, gently rock the guide side to side while pulling the guide forward until the guide is fully out of the track.
6. Inspect the trough guide assembly for damage. If damage is found, inspect the track for broken pieces and remove them.
7. To install, reverse the removal procedure.
- Align the roof opening panel. For additional information, refer to Roof Opening Panel Alignment Adjustments.