Pinpoint Test C: The Alarm System Does Not Arm/No Turn Signal Flash Confirmation
Anti-Theft
Pinpoint Tests
Pinpoint Test C: The Alarm System Does Not Arm/No Turn Signal Flash Confirmation
Normal Operation
The Smart Junction Box (SJB) controls the perimeter alarm system and based on inputs, either arms, disarms or triggers the alarm. When the alarm is triggered, the SJB sounds the horn and flashes the turn signals in regular intervals. The SJB receives inputs for the door lock status, hood ajar, liftgate ajar, door ajar, and the keyless entry keypad. The SJB also receives signals from the Remote Keyless Entry (RKE) transmitters.
For the perimeter alarm to arm and provide a flash of the turn signals, the following conditions must be met:
- Ignition must be OFF
- The hood closed
- All doors closed
- The liftgate closed
- An electronic lock command received from an RKE transmitter, keyless entry keypad, driver door lock cylinder, or door lock control switch (front door opened and then shut after lock is pressed).
Once all the conditions are met, the alarm system enters a pre-arm phase and begins a 20-second countdown. After 20 seconds have passed and no unlock command is received or any hood, door or liftgate is opened, the perimeter alarm arms.
The perimeter alarm is triggered when any door, the hood, or the liftgate is opened without an electronic unlock command from an RKE transmitter, keyless entry keypad or the driver door lock cylinder is received first.
This pinpoint test is intended to diagnose the following:
- Door ajar input
- Hood ajar input
- Liftgate ajar input
- Turn signals
- Keyless entry keypad concern
- RKE transmitter concern
- SJB
PINPOINT TEST C: THE ALARM SYSTEM DOES NOT ARM/NO TURN SIGNAL FLASH CONFIRMATION
-------------------------------------------------
C1 RETRIEVE THE RECORDED DTCs IN THE SJB
- Retrieve the recorded DTCs from the SJB self-test.
- Is DTC B1520 present?
Yes
GO to Pinpoint Test B. Pinpoint Test B: DTC B1520
No
GO to C2.
-------------------------------------------------
C2 CHECK THE COURTESY LAMP OPERATION
- Open and close all the doors and liftgate while checking the courtesy lamp operation.
- Do the courtesy lamps operate correctly?
Yes
GO to C3.
No
REFER to Interior Lighting Testing and Inspection.
-------------------------------------------------
C3 VERIFY THE HAZARD LAMP OPERATION
- Place the hazard switch in the ON position.
- Do the hazard lamps operate correctly?
Yes
GO to C4.
No
REFER to Exterior Lighting Testing and Inspection.
-------------------------------------------------
C4 CHECK THE RKE TRANSMITTER FUNCTION
- Using the RKE transmitter, lock and unlock the doors and operate the panic function.
- Do the RKE transmitter functions operate correctly?
Yes
GO to C5.
No
REFER to Handles, Locks, Latches and Entry Systems Testing and Inspection.
-------------------------------------------------
C5 CHECK THE KEYLESS ENTRY KEYPAD FUNCTION
- Lock the doors using the keyless entry keypad.
- Do all the doors lock using the keyless entry keypad?
Yes
GO to C6.
No
REFER to Handles, Locks, Latches and Entry Systems Testing and Inspection.
-------------------------------------------------
C6 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
Yes
INSTALL a new SJB. REFER to Multifunction Electronic Modules Service and Repair. TEST the system for normal operation.
No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
-------------------------------------------------