Operation CHARM: Car repair manuals for everyone.

Pinpoint Test Z: The Trailer Stop/Turn Lamp Is Inoperative




Trailer Lamps

Pinpoint Tests

Pinpoint Test Z: The Trailer Stop/Turn Lamp Is Inoperative

Refer to Wiring Diagram Set 95, Trailer/Camper Adapter for schematic and connector information. Diagrams By Number

Normal Operation

The Smart Junction Box (SJB) fuse 2 (15A) supplies voltage to both trailer tow stop/turn relays.

The trailer tow LH stop/turn relay coil receives voltage when the vehicle LH rear stoplamp is illuminated. When the trailer tow LH stop/turn relay is energized, the voltage is routed to the trailer tow LH stop/turn relay and the trailer tow connector.

The trailer tow RH stop/turn relay coil receives voltage when the vehicle RH rear stoplamp is illuminated. When the trailer tow RH stop/turn relay is energized, the voltage is routed to the trailer tow RH stop/turn relay and the trailer tow connector.

This pinpoint test is intended to diagnose the following:

- Fuse
- Wiring, terminals or connectors
- Trailer tow connector
- Trailer tow stop/turn relay
- Trailer
- SJB


PINPOINT TEST Z: THE TRAILER STOP/TURN LAMP IS INOPERATIVE

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

NOTE: Before beginning diagnostics, visually inspect the trailer tow connector mounted on the bumper for signs of corrosion or damage. Repair or install a new trailer tow connector as required.

-------------------------------------------------
Z1 DETERMINE IF BOTH TRAILER STOP/TURN LAMPS ARE INOPERATIVE


- Ignition OFF.
- Determine if both trailer stop/turn lamps are inoperative.
- Are both trailer stop/turn lamps inoperative?

Yes
VERIFY the SJB fuse 2 (15A) is OK. If OK, GO to Z2. If not OK, REFER to the Wiring Diagrams to identify the possible causes of the circuit short. Diagrams By Number

No
GO to Z3.

-------------------------------------------------
Z2 CHECK THE TRAILER TOW STOP/TURN RELAY VOLTAGE SUPPLY CIRCUIT FOR AN OPEN


- Disconnect: Trailer Tow LH Stop/Turn Relay.
- Disconnect: SJB C2280d.
- Measure the resistance between the trailer tow LH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and the SJB C2280d-13, circuit SBP02 (YE/RD), harness side.




- Is the resistance less than 5 ohms?

Yes
GO to Z9.

No
REPAIR circuit SBP02 (YE/RD) for an open. Test the system for normal operation.

-------------------------------------------------
Z3 CHECK FOR VOLTAGE THROUGH THE TRAILER TOW CONNECTOR


- Connect: SJB C2280d.
- For the LH trailer stop/turn lamp, while applying the brake pedal, measure the voltage between the trailer tow connector LH stop/turn lamp voltage supply pins, circuit CAT06 (YE), component side and ground.




- For the RH trailer stop/turn lamp, while applying the brake pedal, measure the voltage between the trailer tow connector RH stop/turn lamp voltage supply pins, circuit CAT09 (GN), component side and ground.




- Is the voltage greater than 10 volts?

Yes
The vehicle is operating correctly. SEND the trailer to an authorized camper/trailer repair facility.

No
GO to Z4.

-------------------------------------------------
Z4 CHECK THE TRAILER TOW STOP/TURN CIRCUIT FOR VOLTAGE


- Disconnect: Trailer Tow C4099.
- For the LH trailer stop/turn lamp, while applying the brake pedal, measure the voltage between the trailer tow C4099-1, circuit CAT06 (YE), harness side and ground.




- For the RH trailer stop/turn lamp, while applying the brake pedal, measure the voltage between the trailer tow C4099-4, circuit CAT09 (GN), harness side and ground.




- Is the voltage greater than 10 volts?

Yes
INSTALL a new trailer tow connector. TEST the system for normal operation.

No
GO to Z5.

-------------------------------------------------
Z5 CHECK THE TRAILER TOW STOP/TURN RELAY


- Disconnect: Suspect Trailer Tow Stop/Turn Relay.
- Substitute a known good relay.
- For the LH trailer stop/turn lamp, while applying the brake pedal, measure the voltage between the trailer tow C4099-1, circuit CAT06 (YE), harness side and ground.




- For the RH trailer stop/turn lamp, while applying the brake pedal, measure the voltage between the trailer tow C4099-4, circuit CAT09 (GN), harness side and ground.




- Is the voltage greater than 10 volts?

Yes
REMOVE the known good relay. INSTALL a new trailer tow stop/turn relay. TEST the system for normal operation.

No
REMOVE the known good relay. GO to Z6.

-------------------------------------------------
Z6 CHECK FOR VOLTAGE TO THE TRAILER TOW STOP/TURN RELAY COIL


- For the trailer tow LH stop/turn relay, while applying the brake pedal, measure the voltage between the trailer tow LH stop/turn relay pin 1, circuit CLS18 (GY/BN), BJB face side and ground.




- For the trailer tow RH stop/turn relay, while applying the brake pedal, measure the voltage between the trailer tow RH stop/turn relay pin 1, circuit CLS19 (VT/OG), BJB face side and ground.




- Is the voltage greater than 10 volts?

Yes
GO to Z7.

No
REPAIR circuit CLS18 (GY/BN) (LH stop/turn) or circuit CLS19 (VT/OG) (RH stop/turn) for an open. TEST the system for normal operation.

-------------------------------------------------
Z7 CHECK FOR VOLTAGE TO THE TRAILER TOW STOP/TURN RELAY SWITCH


- For the trailer tow LH stop/turn relay, measure the voltage between the trailer tow LH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and ground.




- For the trailer tow RH stop/turn relay, measure the voltage between the trailer tow RH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and ground.




- Is the voltage greater than 10 volts?

Yes
GO to Z8.

No
REPAIR circuit SBP02 (YE/RD) for an open. TEST the system for normal operation.

-------------------------------------------------
Z8 CHECK THE TRAILER TOW STOP/TURN RELAY COIL GROUND CIRCUIT FOR AN OPEN


- Measure the voltage between the trailer tow LH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and the trailer tow LH stop/turn relay pin 2, circuit GD120 (BK/GN), BJB face side.




- Measure the voltage between the trailer tow RH stop/turn relay pin 3, circuit SBP02 (YE/RD), BJB face side and the trailer tow RH stop/turn relay pin 2, circuit GD120 (BK/GN), BJB face side.




- Is the voltage greater than 10 volts?

Yes
REPAIR circuit CAT06 (YE) (LH trailer stop/turn) or circuit CAT09 (GN) (RH trailer stop/turn) for an open. TEST the system for normal operation.

No
REPAIR circuit GD120 (BK/GN) for an open. TEST the system for normal operation.

-------------------------------------------------
Z9 CHECK FOR CORRECT SJB OPERATION


- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins

- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?

Yes
INSTALL a new SJB. REFER to Multifunction Electronic Modules Service and Repair. TEST the system for normal operation.

No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.

-------------------------------------------------