Pinpoint Test AY: DTC U0140:00
Instrumentation, Message Center and Warning Chimes
Pinpoint Test AY: DTC U0140:00
Normal Operation
- DTC U0140:00 (Lost Communication With Body Control Module: No Sub-Type Information)- sets in the Instrument Panel Cluster (IPC) if data messages received from the Smart Junction Box (SJB) over the High Speed Controller Area Network (HS-CAN) are missing for greater than 5 seconds. For a complete list of all network messages, refer to Information Bus.
This pinpoint test is intended to diagnose the following:
- SJB (Smart Junction Box)
- IPC (Instrument Panel Cluster)
PINPOINT TEST AY : DTC U0140:00
AY1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify that there is an observable symptom present.
Is an observable symptom present?
Yes
GO to AY2.
No
The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
AY2 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: Network Test.
- Carry out the network test.
Does the SJB (Smart Junction Box) pass the network test?
Yes
GO to AY3.
No
REFER to Information Bus.
AY3 RETRIEVE THE RECORDED DTCs FROM THE IPC (Instrument Panel Cluster) SELF-TEST
- Check for recorded DTCs from the IPC (Instrument Panel Cluster) self-test.
Is DTC U3003:16 or DTC U3003:17 recorded?
Yes
GO to Pinpoint Test BC (U3003:16) or GO to Pinpoint Test BD (U3003:17). Pinpoint Test BC: DTC U3003:16 Pinpoint Test BD: DTC U3003:17
No
GO to AY4.
AY4 RECHECK THE IPC (Instrument Panel Cluster) DTCs
NOTE: If new modules were installed prior to the DTC being set, the module configuration may be incorrectly set during the Programmable Module Installation (PMI) or the PMI (Programmable Module Installation) may not have been carried out.
- Clear the DTCs. Repeat the IPC (Instrument Panel Cluster) self-test.
Is DTC U0140:00 still present?
Yes
INSTALL a new SJB (Smart Junction Box). CLEAR the DTCs. REPEAT the self-test.
If DTC U0140:00 is still present, INSTALL a new IPC (Instrument Panel Cluster). REFER to Instrument Panel Cluster (IPC) . TEST the system for normal operation.
No
The system is operating correctly at this time. The DTC may have been set due to high network traffic.