Operation CHARM: Car repair manuals for everyone.

Test A: The Instrument Cluster Is Inoperative

PINPOINT TEST A: THE INSTRUMENT CLUSTER IS INOPERATIVE


A1-A2:






A3-A5:






Normal Operation
With the ignition switch in the START or RUN position, the instrument cluster receives voltage from the central junction box (CJB) through circuit 15-GG14 (GN/RD). With the ignition switch in the RUN or ACC position the instrument cluster receives voltage from the CJB through circuit 75-GG14 (YE/BU). With the ignition switch in the OFF position, the instrument cluster receives its keep-alive voltage from the CJB through circuit 29-GG14 (OG). The instrument cluster is grounded through circuit 91-GG14 (BK/OG).

DTC B1359 - sets when the instrument cluster senses an open or short to ground on the run/acc circuit 75-GG14 (YE/BU) for more than 15 seconds.

Possible Causes
- Fuse(s)
- Circuit 15-GG14 (GN/RD) open
- Circuit 29-GG14 (OG) open
- Circuit 75-GG14 (YE/BU) open
- Circuit 91-GG14 (BK/OG) open
- Instrument cluster.